Energy equipment · Steam, hot water, power & plant integration

Used Steam Boilers, Steam Turbines & CHP Plants for Sale

Find used steam boilers, steam turbine-generator packages, CHP plant equipment and industrial hot-water boilers for purchase and project evaluation. Compare the documented duties, request a price and technical file, and define the inspection, dismantling, packing and export scope for your project.

Equipment opportunities

Review the technical details for each offer and use its equipment reference when enquiring. The Omnical boiler is a component of the CHP package, so the two references describe the same plant at different levels of scope.

Original installed Siemens SST-300 steam turbine, steam pipework and auxiliaries
Supplied equipment photograph.
Steam turbine-generator package · 2018

Siemens SST-300 Steam Turbine Package

Equipment reference: MR00040

Back-pressure turbine-generator package with Siemens generator and Renk TB-800 gearbox. A compatible high-pressure steam source is assessed separately.

Turbine output: 19.47 / 22.90 MWSteam flow: 125 t/hInlet: 114 / 126 bar(a)

Normal / maximum ratings. Boiler is outside the documented turbine-generator scope.

Installed 1 MW steam turbine generator package
Supplied equipment photograph.
CHP plant package · 2007

1 MW CHP & Steam Turbine Package

Equipment reference: MR00052

Documented CHP plant combining a 1 MW back-pressure turbine-generator with a 10 MW boiler producing 14.5 t/h steam, plus associated plant auxiliaries.

Turbine output: 1 MWBoiler steam: 14.5 t/hLive steam: 23.5 bar(g) / 400°C

Lignite-dust fuel system and plant supply boundaries require an equipment-specific review.

Installed Omnical steam boiler forming part of the CHP plant
Supplied equipment photograph.
Boiler within CHP package · 2007

Omnical Industrial Steam Boiler

Equipment reference: MR00052 · Omnical boiler component

Boiler component of the MR00052 CHP plant. The documented boiler duty is 10 MW with 14.5 t/h steam generation and a lignite-dust firing system.

Boiler duty: 10 MWSteam generation: 14.5 t/hLive steam: 23.5 bar(g) / 400°C

Part of MR00052. Separate supply scope is available for discussion and must be confirmed.

Standardkessel 20 t/h gas and oil steam boiler in installed condition, with burner and gas pipework
Supplied equipment photograph.
Gas / oil steam boiler · 1996

Standardkessel 20 t/h Dual-Fuel Steam Boiler

Equipment reference: MR00050

Standardkessel HD 0601-12 boiler with two Weishaupt dual-fuel burners and a documented economizer. Original manual, drawings and photographs are available for review.

Steam capacity: 20 t/hPermissible pressure: 13 bar(g)Fuel: Natural gas / light fuel oil

Water treatment, deaerator, controls and remaining auxiliaries are confirmed in the final supply scope.

Monochrome illustrative rendering of an upright industrial hot-water boiler with a gas burner
Illustrative rendering. Configuration subject to confirmation; not a photograph or dimensional drawing of the offered unit.
Industrial hot water · Natural gas · 1993

Viessmann Paromat-Triplex Hot-Water Boiler

Equipment reference: MR-HW-1400

A steel heating boiler with a Weishaupt Monarch gas burner for industrial hot-water applications. Technical documentation and historical service records are available for review.

Documented thermal output: 1,400 kW / 1.4 MWFuel: Natural gasYear: 1993

Rating shown from the original installation sheet and 2022 service report. Final model and rating require nameplate verification.

Technical data

Manufacturer / product familyViessmann / Paromat-Triplex
Equipment typeSteel hot-water heating boiler
Year of manufacture1993
Documented thermal rating1,400 kW (1.4 MW); original documented output range 1,220–1,400 kW
Installed fuelNatural gas
BurnerWeishaupt Monarch G7/1 series; year 1993. Exact variant to be confirmed.
Original documented boiler limits6 bar maximum permissible pressure / 120°C maximum permissible flow temperature. These are historical boiler limits, not confirmed current operating settings.
Dimensions / transport weightTo be confirmed for lifting and transport planning
Available recordsOriginal technical documentation, 2022–2023 burner service records and 2023–2024 chimney inspection records
Supply scope / inspectionBoiler, burner and any auxiliaries to be agreed in the quotation. Current condition and inspection arrangements subject to confirmation.

Document review: The original installation sheet and 2022 service report identify a 1,400 kW unit. Later inspection records contain different model/rating entries. The nameplate, current operating limits and safety components require technical review before purchase and recommissioning.

For a useful quotation, include your required water temperature, system pressure, fuel supply, destination and project timing. Maria Roboter can define the dismantling, packing, export and integration scope for your project.

Enquire about MR-HW-1400
ETT FT5 steam turbine in installed condition
Supplied equipment photograph.
Smaller back-pressure turbine · 2003

ETT FT5 + G280 Steam Turbine Generator

Equipment reference: MR00051

Compact back-pressure turbine-generator package for evaluating power recovery from an industrial steam system, with original technical drawings and photographs.

Documented output: 265 kWType: Back-pressureTurbine model: ETT FT5

Inlet pressure differs between datasheet and nameplate; verify the operating limits during technical review.

Off-market equipment opportunities. Current availability, condition, inspection access and final supply boundaries are confirmed before purchase. Supplied photographs document the equipment; they do not establish its present operating status.

Compare the documented duties

Turbine power, boiler duty and steam capacity describe different quantities. Use this overview to shortlist equipment, then review the detailed specifications and your receiving-site requirements.

Equipment / referenceYearDocumented ratingPressure / basisSupply scope
Siemens SST-300 Steam Turbine Package
MR00040
201819.47 / 22.90 MW114 / 126 bar(a)Turbine-generator; separate steam source
1 MW CHP & Steam Turbine Package
MR00052
20071 MW turbine / 14.5 t/h steam23.5 bar(g)CHP package; scope to be confirmed
Omnical Industrial Steam Boiler
MR00052 · boiler component
200710 MW / 14.5 t/h23.5 bar(g)Component of MR00052; not an extra plant
Standardkessel 20 t/h Dual-Fuel Steam Boiler
MR00050
199620 t/h steam13 bar(g) permissibleBoiler, burners, economizer; auxiliaries to agree
Viessmann Paromat-Triplex Hot-Water Boiler
MR-HW-1400
19931,400 kW thermal, documented; nameplate verification required6 bar original boiler limit; current settings to confirmHot-water boiler and gas burner; auxiliaries to agree
ETT FT5 + G280 Steam Turbine Generator
MR00051
2003265 kWDatasheet / nameplate verification requiredTurbine-generator package

bar(a) = absolute pressure. bar(g) = gauge pressure. Siemens output and inlet values are normal / maximum documented conditions.

From equipment selection to receiving-site integration

1. Define the duty

Share your required electrical power, steam capacity or hot-water duty, operating conditions, destination and intended schedule.

2. Review the technical fit

Check documents, condition, supply boundaries, auxiliaries, utilities, emissions and receiving-site interfaces.

3. Agree the project scope

Define the required inspection, dismantling, match-marking, packing, export and installation support for the equipment concerned.

Questions about used energy equipment

Which used energy equipment is listed?

The section lists a Siemens SST-300 turbine-generator package, a 1 MW CHP plant package, its Omnical boiler component, a Standardkessel 20 t/h gas/oil boiler, a Viessmann Paromat-Triplex hot-water boiler with a documented 1,400 kW rating, and an ETT 265 kW back-pressure turbine-generator. The Omnical boiler reference is part of the CHP plant rather than an additional independent plant.

How do I choose a suitable steam turbine?

Compare available steam pressure, temperature and flow with the turbine requirements, then assess exhaust/process-steam demand, electrical connection and operating profile. A project-specific steam balance and integration review establish the technical fit.

Do the turbine packages include a boiler?

The Siemens documentation covers a turbine-generator package and requires a suitable steam source to be assessed separately. The 1 MW CHP documentation includes a boiler and plant auxiliaries. The ETT offer is a turbine-generator package. Confirm the final supply list for the selected reference.

Can I request the CHP boiler as a separate component?

The Omnical boiler is a component of CHP package MR00052. Separate supply is discussed on request and depends on confirmation of the agreed plant and component scope.

How is current condition and availability verified?

Request the latest condition information, available records and inspection arrangements for the chosen reference. Current availability, inspection access and final supply boundaries are subject to confirmation and prior sale.

Can Maria Roboter support dismantling, export and integration?

Maria Roboter can define an equipment-specific scope for technical review, dismantling and match-marking, packing and export logistics. Receiving-site installation and integration support can be discussed for the project.

Buying a used industrial boiler: the project brief

Start with the duty your plant actually needs. Specify steam production in t/h or hot-water heating duty in kW, and state the required pressure and temperature. A hot-water boiler is not a substitute for a steam generator. Keep permissible design limits separate from the operating conditions needed by your process.

Match the fuel and supply boundaries

Record the available fuel and supply conditions. The Standardkessel listing documents gas/oil firing, while the Omnical component documents a lignite-dust system. Do not assume that a different burner or a fuel conversion is included. Identify the boiler, burners, economizer, water treatment, feedwater equipment, controls and safety devices required in your quotation.

Request evidence before planning relocation

Ask for the nameplate, technical file, drawings, operating records and inspection access. Historical reports describe past inspections; they do not establish current certification or permission to operate at a new site. Confirm current condition, shipping dimensions, lifting weights and destination requirements before agreeing the removal and transport plan.

Send one concise enquiry

Include your required duty, operating pressure and temperature, fuel, destination country and target installation date. State whether you need equipment only or a defined scope for dismantling, packing, export and receiving-site support.

Review the Standardkessel gas/oil steam boiler · Review the Omnical boiler component · Review the Viessmann hot-water boiler

Buying a used back-pressure turbine: the compatibility brief

Shortlist a turbine using the steam network, not the headline power figure alone. Provide inlet pressure, temperature and available flow, together with the process-steam pressure and demand downstream. State whether each pressure is absolute, bar(a), or gauge, bar(g).

Check the complete operating envelope

Compare the documented normal and maximum conditions with your intended operation. For the Siemens SST-300 listing, the two turbine ratings refer to different stated conditions; they are not a promise of net plant export. For the ETT listing, the inlet-pressure discrepancy between the datasheet and nameplate must be resolved before accepting an operating limit.

Separate turbine, generator and boiler scope

Review generator voltage, frequency, apparent power, power factor, protection, synchronization and the receiving electrical network with the project engineer. A turbine-generator listing does not automatically include a boiler. The Siemens and ETT opportunities require review of the steam source; the MR00052 CHP file also describes associated boiler and plant equipment, with the final supply boundary agreed separately.

Prepare the quotation request

Send the required power, steam inlet conditions and flow, exhaust/process-steam demand, site voltage/frequency, destination country and schedule. Request the technical file, current inspection arrangements and an itemized scope before ordering.

Review Siemens SST-300 · Review ETT 265 kW · Review the 1 MW CHP package

Discuss your energy equipment requirement

Choose a documented offer or ask us to help you select one. The selection and page link are included in your enquiry automatically.

In the message below, include the required duty, steam or hot-water conditions, available fuel, destination country and installation schedule.